Brivis heater, brivis heating repair Box hill

Gas Heater Ducted Heating service near me | Call 0420982770

Brivis ducted heating Box Hill, 
repairs to these models of Brivis heater series 
BX CC HX SP Multiplex He Me 2P Wombat N
Wombat NXA Buffalo Compact Classic StarPro
Downflow Upflow
Heater system with add-on cooling BRIVIS ICE,

Brivis ducted heating repair,
Brivis heater repairs, 

near Box Hill, 

Tel: 0420 982 770

Specialty in repairs of Electronic models,
Brivis heaters BX CC HX SP Multiplex He Me 2P Wombat Buffalo Compact CompactClassic StarPro Downflow Upflow, 

. Approved parts with full warranty, 
. Quick service. Best price everyday , 
. Genuine business. Over 20 years experienced 

Repair Brivis ducted heating problems, 
Control module, Main boards, pcb, Ignitor pcb
Motor, Zone system, Wall control, Flame sensor
Room blower, Motor, Switch, combustion Fan
Electrical, Electronic, Wiring, Relay, Timer
Circuit boards, Display, Solenoid, Gas valve pcb,
Brivis ICE refrigerated cooling add on system,
Error code Spanner on controller, and MORE, 
.  

. from $180 Main module preventative service, circuit rejuvenate, trouble shooting.

. from $80 Module, electric pcb: Workshop testing, fault finding.

Onsite testing and repair of the following ducted heating faults:

FAN Uncontrollable, or continuously, IGNITION problem, weak sparks, Hot surface igniter, ERROR: Fault code errors, LED flashing, random fault, MOTOR bearing and Mechanical noise, NOISE: Intermittent humming noise, Buzzing noise, THERMOSTAT responsive problem, ELECTRICAL CB, RCD trip, GAS VALVE beating noise, Shuts gas valve off intermittently, Will not ignite, SELF RESET, Control board self resetting, Heating CYCLING, heater attempts to start then shut down immediately, NOT RESTART, Will not restart after the first heating cycle, Heater’s reached set room temperature then stop working and will not restart, Service SPANNER and service ERROR CODE on display, Requires MANUAL RESET on controller so often, INTERMITTENT locking noise from the gas valve, Room FAN BLOWER MOTOR not working, PILOT not working.

Repairs to all Brivis heater module, pcb, 
Obsolete electronic parts. HVAC-R circuits, 
Brivis ducted heating add on Brivis ICE cooling, 

Brivis Classic Series Brivis 2P Wombat 15, 20, 20XA, 26, 26XA, Brivis Buffalo 15, 20, 20XA, 26XA, Brivis Downflow 20, 20XA, Brivis Upflow 20, 20XA, 26, 26XA,

Brivis Compact Classic Series CC315IN, CC320IN, CC320IN-XA, CC325IN, CC325IN-XA, CC330IN, CC330IN-XA,

Brivis StarPRo SP4 Series SP415, SP421, SP430, SP435,

Brivis StarPro MX Series MX21E, MX21E-XA, MX21I, MX21I-XA, MX30E, MX30E-XA, MC30I, MC30I-XA, MX35I,

Brivis Buffalo 5 Star Series BX520 BX526,

Brivis StarPro Sp5 Series SP515IN, SP521EN, SP521EN-XA, SP521IN, SP521IN-XA, SP530EN, SP520EN-XA, SP530IN, SP530IN-XA, SP535IN,

Brivis StarPro HX Series HX15I, HX23E, HX23E-XA, HX23I, HX23I-XA, HX30E, HX30E-XA, HX30I, HX-30I-XA, HX35I,

Brivis StarPro SP6 Series Sp615IN, SP623EN, SP623EN-XA, SP623IN, SP623IN-XA, SP630EN, SP630EN-XA, SP630IN, SP630IN-XA, SP635IN,

. Best prices everyday.
. Genuine and insured business.
. Approved parts with warranty.
. Prompt. Honest. Experienced.

———————————

Tel: 0420 982 770

———————————-

If your heater is not working as it should: 

90% changes are the Electronic parts faulty.
You then have 4 choices:

(1). Replace whole new system regardless the manufacturer's diagnostic error code, because you had 3 quotes from an electrician, plumber and a handyman.

(2). Utilising my specialty heating electronic repair skills making the heater back to work as soon as you possibly want; ''If its beyond repair'': You only pay me for the fault finding.

(3). Call manufacturer: Pay call out fee. Until appointment, take a day-off-work, senselessly wait for the tech arrives. So far, no repair guaranteed.

(4). Call local heating repair contractors: Same as the (3), some charge excessively just to come, Some are even lacking manufacturer training and equipment.

. All modern BRIVIS ducted heaters have CPU and Electronic circuits, these are way too difficult for an average trade person who then often suggesting a new system replacement. Before that, call us for a final inspection: The problem sometimes just simply a fault component on electrical system, or can be rectified as cheap as a fraction the costs compared to replacing a whole new heating system.

Fix2Qik Refrigeration, Air conditioning © Allright Reserved.


heating-cooling-split system

Tel: 0420 982 770


Brivis heater error code reset service and repairs,

Brivis EMS, MPS, StarPro, BMax, SP, BX models,

Error30, FAN_LIMP, Fault code FAN SENSOR,
Error31, RoLL_TERR, WRONG FLAME sequence,
Error32, DATA_Err, CONTROL module malfunction,
Error35, No_SA-THM, Thermistor circuit faulty,
Error36, BAdSA-THM, Thermistor circuit faulty,
Error37, TACHO-Err, Irregular MOTOR speed,
Error40, OHEAT_xx, Fault code OVERHEAT,
Error41, OHEAT_xx, Fault code OVERHEAT,
Error42, OHEAT_xx, Fault code OVERHEAT,
Error43, OHCoolDwn, Motor Cooling ON, from 40, 41, 42,
Error44, RoLLOut, FlAME detected on Afro rod,
Error45, LOW24VOLT, Insufficient POWER SUPPLY,
Error46, IGN_RETRY, Too MANY Ignition attempts,
Error47, IGN_RETRY, Fail to light in time,
Error50, IGN_LKOUT, Ignition LOCKOUT no Burner,
Error51, FLMS_LOSS, Pilot FLAME unsuccessful,
Error52, FLM_NOGAS, FLAME On while VAVLE’s Off,
Error53, OH_LKOUT, 2 consecutive OVER-TEMPERATURE,
Error54, RoL_LKOUT, LOCKED after 3 of Error 44,
Error55, IGNINVALID, Lost Flame in 10 seconds,
Error56, PowER_UPD, Power Interrupt, Unreached Vacuum,
Error60, MOTOR_O-C, Fan MOTOR problem,
Error61, 503_FAIL1, NG1/lo main control failure,
Error62, HSI_LOCK, Electronic IGNITOR problem,
Error63, 503_FAIL5, NG1/lo Main control trouble,
Error64, 503_FAIL, NG1/lo EEPROM loading failure,
Error65, MTR_LKOUT, Main Motor room fan stalling,
Error67, 503_WD, NG/lo PCB faulty,
Error68, 503nCCFG_Err, NG/lo PCB faulty,
Error69, FUSE_BLOW, 24VAC fuse open circuit,
Error70, FSAFE_LOC, Flame LOSS Back up sensor,
Error71, FSaFE_LOC, Flame LOSS Back up sensor,

Tel: 0420 982 770


Brivis Compact Classic CC3-15,20,25,30,
Error code service, reset and repairs,

One Flash, Over heat Problem,
Two Flash, Unachieved Vacuum,
Three Flash, No start up flame,
Four Flash, Pressure problem lock out,
Five Flash, Ignition problem lock out,
Six Flash, Gas Valve fault, Main Control fault,


Brivis Wombat, Buffalo, DownFlow, Upflow, HCCA621 models,
Error code service, reset and repairs,

One flash, Overheat condition, reset by user,
Two Flashes, Many Overheat detected, LOCK OUT,
Three Flashes, Flame rolls out of heat exchanger,
Four Flashes, Many Roll out, LOCK OUT,
Five Flashes, SAFE Start Lock Out,
Six Flashes, Ignition invalid, LOCK OUT,
Seven Flashes, Gas Valve fail, Lock Out,
Eight Flashes, Frequency, Lock Out,


Brivis Classic Buffalo 52, Buffalo 85,
Buffalo 120, Wombat 52, Wombat 92, Wombat 120,
Upflow 92, Upflow 120, Downflow 92,
TEK311, TEK321, TEK322, BCG-1, TEK331,

Error Codes service, reset and repairs,

LED Code Identification
AOG Green, Error Recovery Occurred,
STAT Green, Thermostat and Fan indicator,
FAN Green, Fan motor is ON,
ECON, not for user,
ROLL, red and Solid, indicates Flame rolled out,
ROLL, red and Flashing, many roll out detected, LOCK OUT,
OH/S, red and Solid, indicates Overheated condition,
OH/S, red and Flashing, Fan On due to Overheated condition,
OH/F, red and Solid, Fans over temperature,
OH/F, red and Flashing, Lock out due to Fans problem,

All LED illuminated, all LED flickering, flashing unrecognisable, Indicates Control PCB problem.

Tel: 0420 982 770

Please contact me for a solution if there is any other abnormal operating condition of your heater, and rest assure that I am taking care of the problem promptly,



ducted-heater-house-1

Common Faults

Electronics and electro-mechanical parts are the major cause of over 90% heater’s faults, and you would likely experiencing symptom like these: (not all listed).

. Sensor problems: Flame cycling. Fan short cycling. Over heat activated. Thermostat intermittent. Limiting switch open circuit or dead short. Irregular heating.

. Main control module problems
: Ignition problem. Constant fan motor. Speed invariable. Vacuum switch malfunction. Main burner flame will not stay on. No heat. Fan cold air only. Slow start up or slow cut off.
. Power supply problems: Switches. Contactor chattering. Burnt Wiring loop. Relay arc over. 24V transformer short circuit, open circuit. Power regulator pack melting. Electrical smell. Unsettling leak detection. Unresponsive sensors. DC circuits. DC direct Drive. Trips main CB, RCD at main switch box.
. Mechanical and electrical problems: Fan motors. Main blower fan, combustion fan. Noisy fans. Weak blowing. Unregulated air circulation. Faulty mounting plate; Disfuser (diffuser) broken; Clip; Vent; Ducting; Grille broken.
. Duct works and air distribution system: Abnormal, incomplete, uneven heating and air blow. Overheat sensors active: Smelly and bacterial contaminated system.
. Electrical 240V AC main: Faulty switch; open circuit isolator; RCD, CB problems; loosing plug and wiring.
. Fixed wall or remote Controller: Ripple thermal room sensing. Wrong indication. Button and touch pads not sensitive. Blurry or dull display. System erratic operation.
These faults also are seen on these brands: Braemar Brivis Bonaire Climate Technologies Lennox Omega Pyrox Stadt Vulcan

ducted-heater-house-4
. There are so many repairs of ducted heater faults that found related to electric and digital UPC control modules.
The 90% of common heater’ faults roughly comprising of: 80% Electric parts failure; And slightly over 10% Electro – Mechanical problems.

Gas valve’s life cycle: A gas valve of a good known brand heater is working fine in upto between 120000 to 150000 cycles. It is normal to see many 30 years old heaters that have been using in average 8 to 10 hours per day, or less of heating are still working fine.

loosely calculation showing more than 1/2 of my heater’s running cost annually is spending on electrical. Because even the gas burner is off, many electric parts are still being energised for the purpose of sensing, safely monitoring and standing-by, waiting to kick the rest of the heater into action once it received instructions from controller.

Electric costs remain virtually the same in summer (yes! summer) if the heater being used in “Fan-only” mode to circulate the nearby cooled air from one air conditioning room; Often from the main living room; to the other areas of the house.

So, Even though categorised as Gas appliance, the 90% of parts that making up the heater are running on electric, proportionally the 90% of all faults are electric related problems.

fix2Qik can repair all the described problems of your gas ducted central heating system to component level, much cheaper than replace new system. Saving money and your precious time for other more important issues. Braemar Brivis Bonaire Climate Technologies Lennox Omega Pyrox Stadt Vulcan

gas-central-duct-heater-logos-2

Local technician repairs Ducted Heating system

All model of Central gas ducted heater

Braemar ducted heating repairs
Brivis ducted heating repairs
Bonaire ducted heater repair
Lennox ducted heating repairs
Climate technologies heater
Omega ducted heating repairs
Pyrox ducted heater repai,
Stadt ducted heating repairs
Vulcan ducted heater repair
Inverter split system heating
Reverse air conditioner heating
Ducted add on refrigerated heating

——————————————

Brivis heating repair technician
Thợ Sửa máy sưởi Brivis lò sưởi âm
加热器维修技师,
Teknikal na pagkumpuni ng pampainit,
हीटर की मरम्मत तकनीशियन,
Teknisi perbaikan pemanas,
ヒーター修理技術者,
អ្នកបច្ចេកទេសជួសជុលម៉ាស៊ីនកំដៅ,
히터 수리 기술자,
हीटर मरम्मत प्रविधि,
ਹੀਟਰ ਦੀ ਮੁਰੰਮਤ ਕਰਨ ਵਾਲੀ ਤਕਨੀਸ਼ੀਅਨ,
ช่างซ่อมเครื่องทำความร้อน,
Технічний ремонт нагрівача,
Техник по ремонту обогревателей,
Τεχνικός επισκευής θερμαντήρα,

Repair to all ducted heater model

Braemar Brivis Bonaire Climate Technologies Lennox Omega Pyrox Stadt Vulcan

Tel: 0420 982 770


Term & Condition:

* Repair guarantee: Part and labour 12 months, or per specified. * All repairs include manufacturer instruction (if any), ESV compliant certificate * Guaranty and refund excluding: OEM recall, factory defect. Freights, travels. Part(s) reclaiming impossible with 30 days including postage delay. Uncollected items will be disposed after 30 days since informed. Free repair quotation and estimate but fault finding, travelling and parking from or to job sites incurring extras: Please call for details.

Disclaimer: Brand names and trademarks are belong to their respective owners, and being used here for descriptive purposes only.. Fix2Qik is not operating the same as a plumbing contractor business. Does not provide quotation on new or old ducting job. Not installing new heating system or change over. No schedule servicing. No carbon monoxide testing. No gas fitting. No plumbing quotes. All plumbing works will be forwarded to the associate tradesmen once required.