Heating repairs, Ducted heater, Ducted heating repairs
(03) 97007059

Breezeair. Braemar. Brivis. Bonaire. Celair. Climate Technololies. Omega. Pyrox. Stadt. Vulcan

Repair ducted heating
Ducted heater repairs
BRAEMAR Brivis BONAIRE Climate Technololies LENNOX Omega PYROX Stadt VULCAN

Specialty in Electronics models

Tel: (03) 9700 7059  [ No installs]

 Approved parts with warranty 
Prompt. Best price everyday 
Over 20 years Experienced 

Module, PCB, Electrical, Flame, Sensor, Motors, Controller, Zone, Switch, Power supply, Wiring, Blower motor, Relay, Display, Solenoid, Electric’s intermittent problem, and more

Repairs to all ducted heaters that incorporated PCB (electronic card), controls, CPU module


If your heater is not working as it should

90% changes are the Electronic parts faulty,
You then have 4 choice,

(1). Replace whole new system regardless the manufacturer's diagnostic error code, because you had 3 quotes from an electrician, plumber and a handyman.

(2). Utilising my specialty heating electronic repair skills making the heater back to work as soon as you possibly want; ''If its beyond repair'': You only pay me for the travelling.

(3). Call manufacturer: Pay call out fee. Until appointment, take a day-off-work, senselessly wait for the tech arrives. So far, no repair guaranteed.

(4). Call local heating repair contractors: Same as the (3), some charge excessively just to come, Some are even lacking manufacturer training and equipment.

. All modern ducted heaters have CPU and Electronic circuits, these are way too difficult for an average trade person who then often suggesting a new system replacement. Before that, call us for a final inspection: The problem sometimes just simply a fault component on electrical system, or can be rectified as cheap as a fraction the costs compared to replacing a whole new heating system.

 


heating-cooling-split systemTel: (03) 97007059


Heater repair technician,
Thợ Sửa máy sưởi, lò sưởi âm,
加热器维修技师,
Teknikal na pagkumpuni ng pampainit,
हीटर की मरम्मत तकनीशियन,
Teknisi perbaikan pemanas,
ヒーター修理技術者,
អ្នកបច្ចេកទេសជួសជុលម៉ាស៊ីនកំដៅ,
히터 수리 기술자,
हीटर मरम्मत प्रविधि,
ਹੀਟਰ ਦੀ ਮੁਰੰਮਤ ਕਰਨ ਵਾਲੀ ਤਕਨੀਸ਼ੀਅਨ,
ช่างซ่อมเครื่องทำความร้อน,
Технічний ремонт нагрівача,
Техник по ремонту обогревателей,
Τεχνικός επισκευής θερμαντήρα,


Repairs and Service

Brands and models

(Specialty in Ducted heater, Central ducted heating, heater incorporated an electric controls module)

Braemar Brivis Bonaire Climate Technologies Lennox Omega Pyrox Stadt Vulcan

Tel: (03) 9700 7059

Approved parts, warranty, Best price, Insured business, 20 years experienced, Quick, Honest.


 

ducted-heater-house-1

Common Faults:

Electric and electro-mechanical parts are the major cause of over 90% heater’s faults, and you would likely experiencing symptom like these: (not all listed).

. Sensor problems: Flame cycling. Fan short cycling. Over heat activated. Thermostat intermittent. Limiting switch open circuit or dead short. Irregular heating.

. Main control module problems
: Ignition problem. Constant fan motor. Speed invariable. Vacuum switch malfunction. Main burner flame will not stay on. No heat. Fan cold air only. Slow start up or slow cut off.
 
. Power supply problems: Switches. Contactor chattering. Burnt Wiring loop. Relay arc over. 24V transformer short circuit, open circuit. Power regulator pack melting. Electrical smell. Unsettling leak detection. Unresponsive sensors. DC circuits. DC direct Drive. Trips main CB, RCD at main switch box.
 
. Mechanical and electrical problems: Fan motors. Main blower fan, combustion fan. Noisy fans. Weak blowing. Unregulated air circulation. Faulty mounting plate; Disfuser (diffuser) broken; Clip; Vent; Ducting; Grille broken.
 
. Duct works and air distribution system: Abnormal, incomplete, uneven heating and air blow. Overheat sensors active: Smelly and bacterial contaminated system.
 
. Electrical 240V AC main: Faulty switch; open circuit isolator; RCD, CB problems; loosing plug and wiring.
 
. Fixed wall or remote Controller: Ripple thermal room sensing. Wrong indication. Button and touch pads not sensitive. Blurry or dull display. System erratic operation.
 
The faults are recorded on these brands: Braemar Brivis Bonaire Climate Technologies Lennox Omega Pyrox Stadt Vulcan

ducted-heater-house-4
. There are so many modern heater’s faults that related to electric and digital microprocessor control modules.
The 90% of common heater’ faults roughly comprising of: 80% Electric parts failure; And slightly over 10% Mechanical problems.

Gas valve’s life cycle: A gas valve of a good known brand heater is working fine in upto between 120000 to 150000 cycles. It is normal to see many 30 years old heaters that have been using in average 8 to 10 hours per day, or less of heating are still working fine. Calculation showing more than 1/2 of my heater’s running cost annually is spending on electrical. Because even the gas burner is off, many electric parts are still being energised for the purpose of sensing, safely monitoring and standing-by, waiting to kick the rest of the heater into action once the received instructions from its wall controller.

loosely calculation showing more than 1/2 of my heater’s running cost annually is spending on electrical. Because even the gas burner is off, many electric parts are still being energised for the purpose of sensing, safely monitoring and standing-by, waiting to kick the rest of the heater into action once it received instructions from controller.

Electric cost remains virtually the same in summer (yes! summer) if the heater being used in “Fan-only” mode to circulate the nearby cooled air from one air conditioning room; Often from the main living room; to the other areas of the house.

So, Even though categorised as Gas appliance, the 90% of parts that making up the heater are running on electric, proportionally the 90% of all faults are electric related problems.

fix2Qik can repair all the described problems of your ducted gas heating system to component level, QUICK and CHEAPER than most repairers out there. Saving money and your precious time for other more important issues.  Braemar Brivis Bonaire Climate Technologies Lennox Omega Pyrox Stadt Vulcan
 

gas-central-duct-heater-logos-2


Service suburbs:

Endeavour Hills,Doveton,Eumemmerring,Heatherton,Hallam,Dandenong,Dandenong North,Dunearn,Lysterfield South,Noble Park North,Rowville,Narre Warren North,Lysterfield,Fountain Gate,Hampton Park,Waverley Gardens,Noble Park,Narre Warren,Sandown Village,Dandenong South,Harkaway,Lynbrook,Wheelers Hill,Mountain Gate,Upper Ferntree Gully,Upwey,Belgrave Heights,Belgrave South,Springvale,Springvale South,Keysborough,Bangholme,Knoxfield,Narre Warren East,Narre Warren South,Lyndhurst,Ferntree Gully,Tecoma,Sassafras Gully,Berwick,Knox City Centre,Chadstone,Wantirna South,Selby,Belgrave,Clayton South,Dingley Village,Scoresby, Glen Waverley,Boronia,Clayton,Notting Hill,Ferny Creek,Beaconsfield,Cranbourne North,Sandhurst,Pinewood,Wantirna,,Clarinda,Moorabbin Airport,Aspendale Gardens,Braeside,Waterways,Chelsea Heights,Sherbrooke,Beaconsfield Upper,Vermont South,Syndal,Bayswater,Menzies Creek,Huntingdale,Oakleigh South,Aspendale,Patterson Lakes,Carrum Downs,Sassafras,Dewhurst,and other nearby Melbourne’s suburb.


Term & Condition:

* Repair guarantee: Part and labour 12 months. * All repairs include manufacturer instruction (if any), ESV compliant certificate * Guaranty and refund excluding: OEM recall, factory defect. Freights, travels. Part(s) reclaiming impossible with 30 days including postage delay. Uncollected items will be disposed after 30 days since informed.

Fix2Qik © All right reserved. 

Disclaimer: Brand names and trademarks are belong to their respective owners, and being used here for descriptive purposes only.. Fix2Qik is not operating the same as a plumbing contractor business. Does not provide quotation on new or old ducting job. Not installing new heating system or change over. No schedule servicing. No carbon monoxide testing. No gas fitting. No plumbing quotes. All plumbing works will be forwarded to the associate tradesmen once required.